Lab Results
Category: Healthcare Standards
Node id: lab-results
Standards: HIPAA, GDPR, SOC2
Processes laboratory test results with validation, clinical interpretation, trend analysis, and critical value alerting
What it does
- Laboratory result validation against reference ranges
- Clinical interpretation with normal/abnormal/critical classification
- Trend analysis across sequential lab values
- Critical value alerting for life-threatening results
- Support for common lab panels (CBC, BMP, CMP, lipid, liver, thyroid)
Use cases
- Automated lab result interpretation for clinical review
- Critical value notification in lab information systems
- Longitudinal lab trend tracking for chronic disease management
- Lab result validation before EHR import
Runtime
- Performance tier:
fast
Input ports
| Name | Type | Required | Description |
|---|---|---|---|
test_name | text | Yes | Laboratory test name (e.g., glucose, potassium) |
value | number | Yes | Numeric test result value |
unit | text | No | Result unit of measurement |
values | json | No | Array of values for trend analysis |
Output ports
| Name | Type | Required | Description |
|---|---|---|---|
result | json | No | Lab results data (validation, interpretation, trends, alerts) |
is_critical | boolean | No | Whether value is critical |
success | boolean | No | Operation success flag |
Settings
Basic
| Setting | Name | Type | Required | Default | Allowed values | Description |
|---|---|---|---|---|---|---|
| Operation | operation | enum | No | process | process, interpret, validate, trend, alert | Lab results operation to perform |
| Unit | unit | string | No | Expected unit of measurement |
Errors
| Code | Description |
|---|---|
TEST_NAME_REQUIRED | Laboratory test name is required |
VALUE_REQUIRED | Numeric test result value is required |
UNKNOWN_TEST | Test name not recognized in reference database |
UNSUPPORTED_OPERATION | Operation not recognized |
Runtime notes
- is_critical is true when value falls outside critical_low/critical_high thresholds — use it for alert routing
- result shape varies by operation — process includes validation+interpretation+alert, trend includes delta/mean/direction
- Built-in reference ranges cover glucose, hemoglobin, WBC, potassium, creatinine; unknown tests use generic 0-100 range
- trend operation requires a values array with at least 2 numeric entries
See Build any workflow for how to put nodes together and Ports, types and data flow for how port types connect.
Quelque chose n'est pas clair ? Envoyez vos commentaires sur la documentation par courriel.