Saltar al contenido principal

PHI Re-associate (Seam)

Category: Security
Node id: phi-reassociate
Maturity: beta
Risk tier: C

Standards: GDPR Art. 4(5), GDPR Art. 9, LOPDGDD DA 17ª, IEC 62304 Class C

Hospital-only: re-associates PSN pseudonym tokens and shifted dates in a returned Generation Result (C1/C2/C3) using the HG-20 correspondence table; rejects unknown or cross-patient tokens; stores results hospital-side and outputs only ids and counts.

What it does​

  • phi
  • database
  • reidentifies

Use cases​

  • Re-associating the P7 Generation Results of the HGUGM pilot on the hospital for the blind review
  • Returning tenant-drafted documents to the data holder without the correspondence table ever leaving it

Runtime​

  • Performance tier: medium
  • Effect: write

Input ports​

NameTypeRequiredDescription
generationsjsonYesOne Generation Result (tietai.seam.generation-result/v1) or an array of them; each element is processed independently.

Output ports​

NameTypeRequiredDescription
resultsjsonNoPer document: {package_id, document_type, record_version, status, outcome, output_id, reason_codes}. No content, names, identifiers or dates.
countsjsonNoPHI-free totals of the batch.
successbooleanNoTrue when at least one document is stored (or was already stored).

Settings​

Advanced​

SettingNameTypeRequiredDefaultAllowed valuesDescription
Fail on any rejectionfail_on_any_rejectionbooleanNofalseWhen true, one rejected document fails the node so the mesh redelivers. The pilot uses false and routes rejections to the hospital review queue.

Errors​

CodeDescription
SEAM_NOT_DATA_HOLDERNot on the data-holder site, or the seam dependencies are not wired (canonical name; emitted today as its alias SEAM_NOT_HOSPITAL)
SEAM_NOT_HOSPITALDeprecated alias of SEAM_NOT_DATA_HOLDER; the code currently emitted
KEY_MISMATCHA correspondence row does not re-derive its token, or the stored date offset differs (wrong key after a restore)
DB_ERRORThe store or the audit chain failed; nothing was stored for the affected documents
SEAM_INPUTNo generations input

Runtime notes​

  • Requires HYDRA_SITE_RESIDENCY=data-holder (deprecated alias: hospital), the seam keys and the correspondence store; refuses to run otherwise (SEAM_NOT_HOSPITAL).
  • Never wire this node towards a hop-out: its segment must stay on the data holder (HG-22 pins refuse a path from a reidentifies node to hop-out).
  • Rejections (UNKNOWN_TOKEN, MALFORMED_TOKEN, CROSS_PATIENT_TOKEN, UNKNOWN_PACKAGE, SPAN_MAP_MISSING, RECORD_MISMATCH) store nothing for that document, log the attempt and open a seam_reassociation review.
  • A redelivery with the same input hash returns the existing output id; a different input for the same (consult, document type, record version) is a CONFLICTING_REDELIVERY and opens a review.
  • Re-associated content is read only through GET /api/seam/reassociated/{id} (read:hydra.seam.reassociated); every read is audited.

See Build any workflow for how to put nodes together and Ports, types and data flow for how port types connect.