Saltar al contenido principal

Vitals Processing

Category: Healthcare Standards
Node id: vitals-processing

Standards: HIPAA, GDPR, SOC2

Processes vital signs with validation, unit conversion, trend analysis, and critical value alerting

What it does​

  • Vital sign validation against physiological normal ranges
  • Unit conversion (e.g., Fahrenheit to Celsius, lbs to kg)
  • Trend analysis across sequential vital sign readings
  • Critical value alerting with severity classification
  • Support for all standard vital types (HR, BP, RR, SpO2, temp, glucose)

Use cases​

  • Real-time patient monitoring in clinical workflows
  • Early warning score calculation from vital sign trends
  • Unit standardization in multi-system data integration
  • Critical value notification for nursing alerts

Runtime​

  • Performance tier: fast

Input ports​

NameTypeRequiredDescription
valuenumberYesVital sign numeric value
vital_typetextNoType of vital sign (can also be set via config)
unittextNoUnit of measurement
valuesjsonNoArray of values for trend analysis

Output ports​

NameTypeRequiredDescription
resultjsonNoVital signs data (processed values, validation, conversion, trends, alerts)
is_criticalbooleanNoWhether value is critical
successbooleanNoOperation success flag

Settings​

Basic​

SettingNameTypeRequiredDefaultAllowed valuesDescription
OperationoperationenumNoprocessprocess, convert, validate, trend, alertVitals processing operation
Vital Typevital_typeenumNotemperature, heart_rate, respiratory_rate, blood_pressure, oxygen_saturation, weight, height, glucose, systolic_bp, diastolic_bpType of vital sign
UnitunitstringNoUnit of measurement

Advanced​

SettingNameTypeRequiredDefaultAllowed valuesDescription
Source Unitsource_unitstringNoSource unit for conversion
Target Unittarget_unitstringNoTarget unit for conversion

Errors​

CodeDescription
VALUE_REQUIREDNumeric vital sign value is required
VITAL_TYPE_REQUIREDVital sign type must be specified
UNSUPPORTED_CONVERSIONUnit conversion not supported for given types
UNSUPPORTED_OPERATIONOperation not recognized

Runtime notes​

  • Process operation auto-converts to standard units (C, bpm, mmHg, kg, cm) before validation
  • is_critical output is useful for wiring directly to alert/notification nodes
  • Trend analysis requires at least 2 numeric values in the 'values' array input
  • Reference ranges are adult defaults — no age/gender adjustment in current implementation

See Build any workflow for how to put nodes together and Ports, types and data flow for how port types connect.