Vitals Processing
Category: Healthcare Standards
Node id: vitals-processing
Standards: HIPAA, GDPR, SOC2
Processes vital signs with validation, unit conversion, trend analysis, and critical value alerting
What it does
- Vital sign validation against physiological normal ranges
- Unit conversion (e.g., Fahrenheit to Celsius, lbs to kg)
- Trend analysis across sequential vital sign readings
- Critical value alerting with severity classification
- Support for all standard vital types (HR, BP, RR, SpO2, temp, glucose)
Use cases
- Real-time patient monitoring in clinical workflows
- Early warning score calculation from vital sign trends
- Unit standardization in multi-system data integration
- Critical value notification for nursing alerts
Runtime
- Performance tier:
fast
Input ports
| Name | Type | Required | Description |
|---|---|---|---|
value | number | Yes | Vital sign numeric value |
vital_type | text | No | Type of vital sign (can also be set via config) |
unit | text | No | Unit of measurement |
values | json | No | Array of values for trend analysis |
Output ports
| Name | Type | Required | Description |
|---|---|---|---|
result | json | No | Vital signs data (processed values, validation, conversion, trends, alerts) |
is_critical | boolean | No | Whether value is critical |
success | boolean | No | Operation success flag |
Settings
Basic
| Setting | Name | Type | Required | Default | Allowed values | Description |
|---|---|---|---|---|---|---|
| Operation | operation | enum | No | process | process, convert, validate, trend, alert | Vitals processing operation |
| Vital Type | vital_type | enum | No | temperature, heart_rate, respiratory_rate, blood_pressure, oxygen_saturation, weight, height, glucose, systolic_bp, diastolic_bp | Type of vital sign | |
| Unit | unit | string | No | Unit of measurement |
Advanced
| Setting | Name | Type | Required | Default | Allowed values | Description |
|---|---|---|---|---|---|---|
| Source Unit | source_unit | string | No | Source unit for conversion | ||
| Target Unit | target_unit | string | No | Target unit for conversion |
Errors
| Code | Description |
|---|---|
VALUE_REQUIRED | Numeric vital sign value is required |
VITAL_TYPE_REQUIRED | Vital sign type must be specified |
UNSUPPORTED_CONVERSION | Unit conversion not supported for given types |
UNSUPPORTED_OPERATION | Operation not recognized |
Runtime notes
- Process operation auto-converts to standard units (C, bpm, mmHg, kg, cm) before validation
- is_critical output is useful for wiring directly to alert/notification nodes
- Trend analysis requires at least 2 numeric values in the 'values' array input
- Reference ranges are adult defaults — no age/gender adjustment in current implementation
See Build any workflow for how to put nodes together and Ports, types and data flow for how port types connect.
Etwas unklar? Senden Sie Feedback zur Dokumentation per E-Mail..