ECG Strips Source (Connect MCT)
Category: Healthcare Standards
Node id: ecg-strips-source
Maturity: beta
Risk tier: B
Standards: HIPAA, GDPR
Fetches a patient's stored ECG strips from tietai-connect (MCT) and emits model-ready waveforms (channels + lead + sample rate + gain) for waveform-perception.
What it does
- Reads Connect's ecg_strips store (every ingested format: WFDB, EDF, SCP, ISHNE, MUSE, DICOM-ECG)
- Emits calibrated waveform payloads (raw counts + µV/LSB gain) ready for waveform-perception
- Maps Connect lead configs to standard lead names; skips layouts it cannot represent honestly
Use cases
- Feed MCT/Holter strips into signal-model screening pipelines
- Batch-embed a patient's recent strips for similarity analysis
Runtime
- Performance tier:
medium
Input ports
| Name | Type | Required | Description |
|---|---|---|---|
patient_id | text | No | Patient whose strips to fetch. Falls back to the patient_id config. |
from | text | No | Window start, RFC3339 (Connect defaults to 7 days ago when empty). Overrides the from config. |
to | text | No | Window end, RFC3339 (default now). Overrides the to config. |
Output ports
| Name | Type | Required | Description |
|---|---|---|---|
strips | json | No | Model-ready strips: strip_id, channels [[samples]], leads, sample_rate_hz, gain_uv_per_lsb, recorded_at, quality, rhythm metadata. |
count | number | No | Number of strips emitted. |
warnings | json | No | Strips skipped and why (e.g. unsupported multi-lead layout). |
Settings
Basic
| Setting | Name | Type | Required | Default | Allowed values | Description |
|---|---|---|---|---|---|---|
| Patient ID | patient_id | string | No | Fallback patient id when no patient_id input is wired. | ||
| From (RFC3339) | from | string | No | Fallback window start when no from input is wired. | ||
| To (RFC3339) | to | string | No | Fallback window end when no to input is wired. | ||
| Max Strips | limit | number | No | 50 | Maximum strips to fetch (Connect caps at 500). |
Advanced
| Setting | Name | Type | Required | Default | Allowed values | Description |
|---|---|---|---|---|---|---|
| Lead Label Override | lead_label | string | No | Force the emitted lead name (research use — e.g. treat a SINGLE strip as lead I for ecgfounder-1lead). | ||
| Connect Base URL | connect_base_url | string | No | Override the Connect base URL (default from HYDRA_CONNECT_BASE_URL). |
Errors
| Code | Description |
|---|---|
STRIPS_CONFIG | patient_id missing, or no Connect base URL configured |
STRIPS_REQUEST | Connect was unreachable or returned an error |
Runtime notes
- Requires HYDRA_CONNECT_BASE_URL (or the connect_base_url config).
- Multi-lead (12_LEAD) strips are skipped with a warning in v1 — Connect's flat waveform layout for them is unspecified.
- Strips with no stored gain are treated as µV samples (gain 1.0), matching Connect's ECGPayload contract.
See Build any workflow for how to put nodes together and Ports, types and data flow for how port types connect.